Brand: FUJITSU
Reference: 3NGF89135
1x1 Fujitsu ACY71K-KA split duct Inverter medium pressure air conditioner
1x1 Fujitsu ACY71K-KA Air Conditioner
Cooling capacity kcal / h W 5850 (781-6354) 6800 (900-7400)
Heat output kcal / h W 6455 (781-7388) 7500 (900-8600)
Energy saving ratio (SEER / SCOP) 5.90 / 3.90
Energy saving ratio (EER / COP) 3.11 / 3.75
Cooling / heating energy class A + / A
Voltage / Phases / Frequency V / nº / Hz "230/1/50
Refrigeration / heating electricity consumption kW 2,0 / 2,19
Maximum cooling / heating start current A 12.6 / 12.6
Cooling / heating absorbed intensity A 9.7 / 8.8
Power supply (EU) 3x2.5 + N + T
3x2.5 + T electrical interconnection
Air flow unit Int. Min / Max m³ / h 580/1100
Air flow Unit Ext. (Max.) M³ / h 2885
Sound pressure Unit Int. A / M / B / Q / SQ dB (A) 31/29/27/25 / -
Sound pressure max. Unit Cooling / heating ext. DB (A) 55/54
Standard Static Pressure / Range Pa 35/30 - 150
Dimensions Int. Unit Height / Width / Depth mm 270/1135/700
Dimensions Unit Ext. Height / Width / Depth mm 632/799/290
Net weight Int. Unit / Ext. Unit Kg 35/38
Refrigeration connections diameter - Liquid / Gas Pul 1/4 "/ 1/2"
Max distances Total / Vertical m 25/20
R32 refrigerant
Refrigerant charge Kg (CO2eq-T) "" 1.25 (0.742)
Max distances precharged gas m 15
Additional load gr / m 20
Refrigeration / heating operating range ºC "-10 / 46 / -15 / 24
De cuantos kw es?
5.8kw
5.8kw
Hola la medida de los orificios de salida que diámetro son ? Un saludo
Buenas tardes el diámetro es de 205mm
Hacéis presentaciones?
Buenas tardes, entendemos que pregunta si hacemos instalaciones.
No disponemos que personal para hacer instalaciones.
Buenas tardes. El equipo,es monofasico?. Sirve para calor y frio?. Un saludo y gracias
Buenas tardes Jesus, correcto el equipo es monofasico y lo podrás utilizar tanto para la producción de frío como calor. Atentamente, el equipo de Voltiks.