Brand: SFA SANITRIT
Reference: SKB
Evacuation pumps developed for the evacuation of condensate, for both air conditioning and boilers condensation
4 INPUTS FOR EASY INSTALLATION.
REDUCED SIZE.
RESISTANT TO ACID WATER.
PRINCIPLE OF WORK
These devices work with a level buoy system: when using the air conditioning device or the condensing boiler, the water level rises within the
p>
tank and the pressure activates the system. The turbine immediately evacuates the condensate through the evacuation pipe. The pump can be operated several times depending on the amount of water required. evacuate.
INSTALLATION TIPS
The appliance must be installed so that access
is easy for control and maintenance.
SANICONDENS® Mini and SANICONDENS® Basic
have wall fixing devices.
It is essential to level the pump both in
< p>horizontally and vertically so that the detection buoycan function correctly.
TIPS FOR USE
This device does not need a
< p>particular maintenance.CONNECTIONS
SANICONDENS® Mini and SANICONDENS® Basic have 4 inlets of Ø 28 mm. If necessary, use the inlet reduction
Ø 19/32/40 mm.
Cover the unused inlets with the plugs provided.
If necessary requires a vertical section in the evacuation route, it must be done with a Ø 8 mm tube immediately
at the pump outlet. Carry out the horizontal sections of the evacuation with a larger diameter pipe and with a rigid pipe.
The device must be connected to ground (Class I). Check that the ground resistance is less than 38 Ω.
The connection must serve exclusively to power the device
Basic
Possible connections
air conditioning +
condensing boiler +
refrigerant devices
Vertical evacuation (up to) 4.5 m
Horizontal evacuation (up to a slope
of 1%) 50 m
Inlets Ø 28 mm 4 upper
Outlet diameter 8/11 mm
Recommended Ø of the evacuation tube in
horizontal sections 18 mm rigid
PH min. 2.5
Weight. 1.3 Kg
Power supply 220-240V/50 Hz
Power cable type 3 x 0.75 mm2
+ plug
Amperage 0.52 A
Motor consumption 60 W
Material of the motor shaft stainless steel
Type of turbine blades< /p>
Water resistance index IP 20 I
Power cable length 2 m
Max. of liquids 800 C
Maximum flow rate 342 L/H
Tank volume 1 L
Noise level <45 dB(A)