Everything in electrical equipment, air conditioning and electrical appliances in voltiks
Send to:
Send to:
Customer service , email to info@voltiks.es - DISC5PLUS: 5 € discount some exempt brands. Minimum amount €200

IGA Protector Over Permanent and Transient Tension Single-phase Technological Applications

Brand: Aplicaciones Tecnológicas

Reference: AT-9072

Offer: From €105.43 €85.72 Without VAT
Offer:
PVP: €259.53
€105.43
Quantity
  • In stock. Immediate shipment.
    Taxes included
    Free shipping


Description

IGA TEST COMPACT series protectors cut the line when they detect a permanent overvoltage (eg neutral faults), thus protecting downstream equipment.

Details

More information

The IGA TEST COMPACT series protectors cut the line when

detect a permanent overvoltage (for example, neutral faults),

thus protecting the equipment installed downstream.

To reset the circuit breaker, it is first necessary to reset

the protection coil, for which the RESET button is used.

In addition, the IGA TEST COMPACT protectors also act by detecting

a transient overvoltage by diverting the current to ground and reducing the

voltage at a level not harmful to the connected equipment.

Tested and certified as a type 2 protector in official laboratories and

independent according to standard UNE-EN 61643-11 and GUÍA-BT-23 of the REBT.

It has a thermodynamic device for disconnection from the electrical network

in case of degradation and surge warning system

transitory. When the buzzer glows green, the protector is on

good condition. If not, replace.

The integrated circuit breaker is available for the currents

typical ratings: 6, 10, 16, 20, 25, 32, 40, 50 and 63 A.


> INSTALLATION

It is installed in series with the low voltage line, between the switch

power control (ICP) and differential switch (ID), connecting it

to Earth.

The installation must be done without tension in the line.


This protector is composed of a protection coil against

permanent overvoltages, which includes a protector against

transient overvoltages, associated with an automatic switch.



Reference: AT-9071 AT-9072 AT-9073 AT-9074 AT-9075

Nominal current: 25 A 32 A 40 A 50 A 63 A

Rated voltage: Un 230 VAC

Maximum overvoltage: 400 VAC

Actuation voltage: Ua 265 - 280 VAC

Actuation time: @ 275 V → 8 - 10 s / @ 400 V → 0.1 - 0.2 s

Cutting capacity: 6 kA

Type of tests according to

UNE- EN 61643-11: Type 2

Rated current

discharge: I

n 5 kA

Maximum current: I

max 15 kA

Protection level: Up 1.5 kV

Dimensions: 51 x 81 x 65 mm (3 modules DIN43880)

Cable range: Minimum / maximum section: 1.5 / 16 mm2


Single-phase Permanent and Transient Voltage Protector Technological Applications: 32A Single-phase Permanent and Transient Voltage Protector At-9072 Technological Applications

None

The IGA TEST COMPACT series protectors cut the line when


detect a permanent overvoltage (for example, neutral faults),


thus protecting the equipment installed downstream.


To reset the circuit breaker, it is first necessary to reset


the protection coil, for which the RESET button is used.


In addition, the IGA TEST COMPACT protectors also act by detecting


a transient overvoltage by diverting the current to ground and reducing the


voltage at a level not harmful to the connected equipment.


Tested and certified as a type 2 protector in official laboratories and


independent according to standard UNE-EN 61643-11 and GUÍA-BT-23 of the REBT.


It has a thermodynamic device for disconnection from the electrical network


in case of degradation and surge warning system


transitory. When the buzzer glows green, the protector is on


good condition. If not, replace.


The integrated circuit breaker is available for the currents


typical ratings: 6, 10, 16, 20, 25, 32, 40, 50 and 63 A.




> INSTALLATION


It is installed in series with the low voltage line, between the switch


power control (ICP) and differential switch (ID), connecting it


to Earth.


The installation must be done without tension in the line.




This protector is composed of a protection coil against


permanent overvoltages, which includes a protector against


transient overvoltages, associated with an automatic switch.






Reference: AT-9071 AT-9072 AT-9073 AT-9074 AT-9075


Nominal current: 25 A 32 A 40 A 50 A 63 A


Rated voltage: Un 230 VAC


Maximum overvoltage: 400 VAC


Actuation voltage: Ua 265 - 280 VAC


Actuation time: @ 275 V → 8 - 10 s / @ 400 V → 0.1 - 0.2 s


Cutting capacity: 6 kA


Type of tests according to


UNE- EN 61643-11: Type 2


Rated current


discharge: I


n 5 kA


Maximum current: I


max 15 kA


Protection level: Up 1.5 kV


Dimensions: 51 x 81 x 65 mm (3 modules DIN43880)


Cable range: Minimum / maximum section: 1.5 / 16 mm2

Single-phase Permanent and Transient Voltage Protector Technological Applications: 63A Single-phase Permanent and Transient Voltage Protector At-9075 Technological Applications

Description The IGA TEST COMPACT series protectors cut the line when they detect a permanent overvoltage (eg neutral faults), thus protecting downstream equipment.

The IGA TEST COMPACT series protectors cut the line when


detect a permanent overvoltage (for example, neutral faults),


thus protecting the equipment installed downstream.


To reset the circuit breaker, it is first necessary to reset


the protection coil, for which the RESET button is used.


In addition, the IGA TEST COMPACT protectors also act by detecting


a transient overvoltage by diverting the current to ground and reducing the


voltage at a level not harmful to the connected equipment.


Tested and certified as a type 2 protector in official laboratories and


independent according to standard UNE-EN 61643-11 and GUÍA-BT-23 of the REBT.


It has a thermodynamic device for disconnection from the electrical network


in case of degradation and surge warning system


transitory. When the buzzer glows green, the protector is on


good condition. If not, replace.


The integrated circuit breaker is available for the currents


typical ratings: 6, 10, 16, 20, 25, 32, 40, 50 and 63 A.




> INSTALLATION


It is installed in series with the low voltage line, between the switch


power control (ICP) and differential switch (ID), connecting it


to Earth.


The installation must be done without tension in the line.




This protector is composed of a protection coil against


permanent overvoltages, which includes a protector against


transient overvoltages, associated with an automatic switch.






Reference: AT-9071 AT-9072 AT-9073 AT-9074 AT-9075


Nominal current: 25 A 32 A 40 A 50 A 63 A


Rated voltage: Un 230 VAC


Maximum overvoltage: 400 VAC


Actuation voltage: Ua 265 - 280 VAC


Actuation time: @ 275 V → 8 - 10 s / @ 400 V → 0.1 - 0.2 s


Cutting capacity: 6 kA


Type of tests according to


UNE- EN 61643-11: Type 2


Rated current


discharge: I


n 5 kA


Maximum current: I


max 15 kA


Protection level: Up 1.5 kV


Dimensions: 51 x 81 x 65 mm (3 modules DIN43880)


Cable range: Minimum / maximum section: 1.5 / 16 mm2

Single-phase Permanent and Transient Voltage Protector Technological Applications: Single Phase Permanent and Transient Voltage Protector 25A Technological Applications At-9071

Description The IGA TEST COMPACT series protectors cut the line when they detect a permanent overvoltage (eg neutral faults), thus protecting downstream equipment.

The IGA TEST COMPACT series protectors cut the line when


detect a permanent overvoltage (for example, neutral faults),


thus protecting the equipment installed downstream.


To reset the circuit breaker, it is first necessary to reset


the protection coil, for which the RESET button is used.


In addition, the IGA TEST COMPACT protectors also act by detecting


a transient overvoltage by diverting the current to ground and reducing the


voltage at a level not harmful to the connected equipment.


Tested and certified as a type 2 protector in official laboratories and


independent according to standard UNE-EN 61643-11 and GUÍA-BT-23 of the REBT.


It has a thermodynamic device for disconnection from the electrical network


in case of degradation and surge warning system


transitory. When the buzzer glows green, the protector is on


good condition. If not, replace.


The integrated circuit breaker is available for the currents


typical ratings: 6, 10, 16, 20, 25, 32, 40, 50 and 63 A.




> INSTALLATION


It is installed in series with the low voltage line, between the switch


power control (ICP) and differential switch (ID), connecting it


to Earth.


The installation must be done without tension in the line.




This protector is composed of a protection coil against


permanent overvoltages, which includes a protector against


transient overvoltages, associated with an automatic switch.






Reference: AT-9071 AT-9072 AT-9073 AT-9074 AT-9075


Nominal current: 25 A 32 A 40 A 50 A 63 A


Rated voltage: Un 230 VAC


Maximum overvoltage: 400 VAC


Actuation voltage: Ua 265 - 280 VAC


Actuation time: @ 275 V → 8 - 10 s / @ 400 V → 0.1 - 0.2 s


Cutting capacity: 6 kA


Type of tests according to


UNE- EN 61643-11: Type 2


Rated current


discharge: I


n 5 kA


Maximum current: I


max 15 kA


Protection level: Up 1.5 kV


Dimensions: 51 x 81 x 65 mm (3 modules DIN43880)


Cable range: Minimum / maximum section: 1.5 / 16 mm2

Single-phase Permanent and Transient Voltage Protector Technological Applications: Single-phase Permanent and Transient Voltage Protector 40A Technological Applications At-9073

None

The IGA TEST COMPACT series protectors cut the line when


detect a permanent overvoltage (for example, neutral faults),


thus protecting the equipment installed downstream.


To reset the circuit breaker, it is first necessary to reset


the protection coil, for which the RESET button is used.


In addition, the IGA TEST COMPACT protectors also act by detecting


a transient overvoltage by diverting the current to ground and reducing the


voltage at a level not harmful to the connected equipment.


Tested and certified as a type 2 protector in official laboratories and


independent according to standard UNE-EN 61643-11 and GUÍA-BT-23 of the REBT.


It has a thermodynamic device for disconnection from the electrical network


in case of degradation and surge warning system


transitory. When the buzzer glows green, the protector is on


good condition. If not, replace.


The integrated circuit breaker is available for the currents


typical ratings: 6, 10, 16, 20, 25, 32, 40, 50 and 63 A.




> INSTALLATION


It is installed in series with the low voltage line, between the switch


power control (ICP) and differential switch (ID), connecting it


to Earth.


The installation must be done without tension in the line.




This protector is composed of a protection coil against


permanent overvoltages, which includes a protector against


transient overvoltages, associated with an automatic switch.






Reference: AT-9071 AT-9072 AT-9073 AT-9074 AT-9075


Nominal current: 25 A 32 A 40 A 50 A 63 A


Rated voltage: Un 230 VAC


Maximum overvoltage: 400 VAC


Actuation voltage: Ua 265 - 280 VAC


Actuation time: @ 275 V → 8 - 10 s / @ 400 V → 0.1 - 0.2 s


Cutting capacity: 6 kA


Type of tests according to


UNE- EN 61643-11: Type 2


Rated current


discharge: I


n 5 kA


Maximum current: I


max 15 kA


Protection level: Up 1.5 kV


Dimensions: 51 x 81 x 65 mm (3 modules DIN43880)


Cable range: Minimum / maximum section: 1.5 / 16 mm2

Single-phase Permanent and Transient Voltage Protector Technological Applications: Single-phase Permanent and Transient Voltage Protector 50A Technological Applications AT-9074

None

The IGA TEST COMPACT series protectors cut the line when


detect a permanent overvoltage (for example, neutral faults),


thus protecting the equipment installed downstream.


To reset the circuit breaker, it is first necessary to reset


the protection coil, for which the RESET button is used.


In addition, the IGA TEST COMPACT protectors also act by detecting


a transient overvoltage by diverting the current to ground and reducing the


voltage at a level not harmful to the connected equipment.


Tested and certified as a type 2 protector in official laboratories and


independent according to standard UNE-EN 61643-11 and GUÍA-BT-23 of the REBT.


It has a thermodynamic device for disconnection from the electrical network


in case of degradation and surge warning system


transitory. When the buzzer glows green, the protector is on


good condition. If not, replace.


The integrated circuit breaker is available for the currents


typical ratings: 6, 10, 16, 20, 25, 32, 40, 50 and 63 A.




> INSTALLATION


It is installed in series with the low voltage line, between the switch


power control (ICP) and differential switch (ID), connecting it


to Earth.


The installation must be done without tension in the line.




This protector is composed of a protection coil against


permanent overvoltages, which includes a protector against


transient overvoltages, associated with an automatic switch.






Reference: AT-9071 AT-9072 AT-9073 AT-9074 AT-9075


Nominal current: 25 A 32 A 40 A 50 A 63 A


Rated voltage: Un 230 VAC


Maximum overvoltage: 400 VAC


Actuation voltage: Ua 265 - 280 VAC


Actuation time: @ 275 V → 8 - 10 s / @ 400 V → 0.1 - 0.2 s


Cutting capacity: 6 kA


Type of tests according to


UNE- EN 61643-11: Type 2


Rated current


discharge: I


n 5 kA


Maximum current: I


max 15 kA


Protection level: Up 1.5 kV


Dimensions: 51 x 81 x 65 mm (3 modules DIN43880)


Cable range: Minimum / maximum section: 1.5 / 16 mm2

Comments (3)

jean-romain
| 14/10/2021 | Verified purchase
Single-phase Permanent and Transient Voltage Protector Technological Applications

bon produit installation facile

FLORENCIO
| 26/02/2021 | Verified purchase
Single-phase Permanent and Transient Voltage Protector Technological Applications

Fácil de instalar, aunque podría llevar a la confusión ya que la entradas es por abajo si no se tiene el manual, por lo demás el tiempo lo dirá, por ahora no hay tormenta eléctrica y fallos en la red

Ernesto
| 23/07/2020
Single-phase Permanent and Transient Voltage Protector Technological Applications

Primera experiencia con Voltiks y satisfactoria. Buenas atención y plazo correcto. El sobretensiones instalado sin problemas.

How do reviews and ratings work?

The opinions and ratings of the products are mostly made by registered customers who have purchased the product. These reviews appear with a "verified purchase" mark. In any other case this mark does not appear. The rating of the product, out of 5 stars, is obtained with the average of all published reviews of the product. To ensure that the information is useful to other customers, comments and ratings, whether positive or negative, they are published after prior validation.

Questions (1)

juan
12/11/2020

cuando colocas el protector permanente y transitorio , se anula el automático general , y de cuantos amperios seria para la vivienda de 230v. con una potencia de 4000w.

Store response | 16/11/2020

Buenos días, por lo que veo hasta 4,6 KW el IGA es de 20A. El iGA no deja de ser un magnetotérmico asociado a las bobinas que lo hacen saltar por las sobretensiones.

Best price

Have you seen it cheaper?
×

Opinions of our clients

Receive our news

See details + -
By checking this option we will send you the best offers and exclusive promotions and discounts to your email address. You can unsubscribe at any time.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Set your cookies preferences
We use cookies and similar technologies to offer you a personalized, safe, reliable experience and to be able to measure page performance to continue improving our services. For more information or to edit your cookie preferences at any time, check the Cookies policy page
Go out